• Home
  • C703-96(R04): AWWA Standard for Cold-Water Meters--Fire-Service Type (PDF)

C703-96(R04): AWWA Standard for Cold-Water Meters--Fire-Service Type (PDF)

SKU: STC_0060051-PDF
This standard describes the various types and classes of cold-water fire-service type meters in sizes 3 in. (75 mm) through 10 in. (250 mm) and the materials and workmanship used in their fabrication. A fire-service meter shall consist of one of the following: A. A combination of (1) a mainline meter of the proportional type, Underwriter's Laboratory (UL) listed or Factory Mutual Research (FM) approved, having an unobstructed passageway of essentially the pipe size, for measuring high flow rates; (2) a bypass meter of the appropriate size for measuring low flow rates; and (3) an automatic valve for diverting flow rates other than fire demand through the bypass meter. B. A combination of (1) a mainline meter of the turbine type (Class II), UL listed or FM approved; (2) a UL-listed or FM-approved fire-service strainer; (3) a bypass meter of the appropriate size for measuring low flow rates; and (4) an automatic valve for diverting flow rates other than fire demand through the bypass meter. C. A combination of (1) a mainline meter of the turbine type (Class II), UL listed or FM approved; and (2) a UL-listed or FM-approved fire-service strainer.

Description

The major revisions made to the standard in this edition include the following: ASTM standards have been added to the references (Sec. 2); it is recognized in the materials section (Sec. 2) of this standard that advances have been made in the development of nonmetallic materials for water meter construction. Plastic materials are currently used successfully for meter components. The development of new and improved materials is ongoing; therefore, this standard will not require any one specific material but will cite examples of material defined by ASTM specifications and typically used in construction of water meters. The materials section has been modified to recognize these advances; the reference to unsealed or unprotected lead for valve weights has been deleted from Sec. 4.1.10 to comply with the latest USEPA rulings on lead in contact with potable water; the scope (Sec. 1.1) has been expanded to include a turbine (Class II) mainline meter with strainer and bypass as a type of fire-service meter; in Sec. 4.1.2, fabricated steel has been added as a material with which main cases can be made; Table 1 has been revised to reflect manufacturer advances and has been expanded to include short-term deluge maximum flow, flow spread at changeover flow, and accuracy information. Table 1 has also been expanded to include the operating characteristics of the turbine mainline meter with strainer and bypass type of fire service meter; a separate Table 1M has been added; a new Table 5 was added and includes mainline register information that was formerly listed in Table 1; Table 3 (formerly of ANSI/AWWA C703-86) has been deleted and included in the expanded Table 1; in Sec. 4.2.4 the maximum working pressure has been raised from 150 psi (1,030 kPa) to 175 psi (1,200 kPa); a section has been added to appendix A stating AWWA's position on grounding of electrical systems to pipe systems conveying drinking water to customers' premises; the workmanship and materials section has been deleted (Sec. 1.4.2); the format has been changed to AWWA standard style; and, the acceptance clause (Sec. I.C) has been added and the definitions (Sec. 3) have been revised to approved wording.
$142.00 Your price
$99.00member price